View Neutra EQ user manual, PDF
Processing modes
Zero latency, Natural phase, Linear phase, and Hybrid phase.
Document revision 1 · Updated 23 October 2026
For product version 1.0.0
Choose a mode from the phase menu. The header shows the delay in use, in samples.
| Mode | Behavior | Latency |
|---|---|---|
| Zero latency | Minimum-phase processing. | 0 samples |
| Natural phase | Minimum-phase processing with a short fixed delay. | 5 samples |
| Linear phase | Linear-phase filtering with a constant delay set by the resolution menu. | See below |
| Hybrid phase | Minimum-phase bass with a linear-phase high end. | See below |
For phase shaping with All Pass, All Pass x2, All Pass x4, or Disperser, choose Zero latency or Natural phase.
Linear phase resolution
Shorter resolutions add less delay. Longer ones resolve bass and steep filters more accurately.
| Resolution | Samples | At 44.1 kHz | At 48 kHz |
|---|---|---|---|
| Short | 1088 | 25 ms | 23 ms |
| Linear low | 2112 | 48 ms | 44 ms |
| Medium | 5120 | 116 ms | 107 ms |
| High | 9216 | 209 ms | 192 ms |
| Very high | 17408 | 395 ms | 363 ms |
Hybrid phase resolution
Hybrid phase offers Ultra low at 144 samples (3 ms at 48 kHz) and Low at 672 samples (14 ms at 48 kHz). Ultra low is minimum phase below 800 Hz and linear above 2.4 kHz. Low is minimum phase below 300 Hz and linear above 800 Hz.
Page updated 2026-10-21